DC 6V 12V 24V DC Motor Forward And Reverse Regulator 20A High Current Driver Board Limit Relay Lifting Control P0

99,00 RON
Livrare GRATUITĂ

DC 6V 12V 24V DC Motor Forward And Reverse Regulator 20A High Current Driver Board Limit Relay Lifting Control P0

  • Marcă: Unbranded
Vândut de:

DC 6V 12V 24V DC Motor Forward And Reverse Regulator 20A High Current Driver Board Limit Relay Lifting Control P0

  • Marcă: Unbranded

99,00 RON

Economii 50,00 RON (33%)

Preț recomandat

149,00 RON
În stoc
Livrare GRATUITĂ
Vândut de:

99,00 RON

Economii 50,00 RON (33%)

Preț recomandat

149,00 RON
În stoc
Livrare GRATUITĂ

Acceptăm următoarele metode de plată

Descriere

PO version (Self-locking) — Product Description and Key Details Key benefits - Provides reliable self-locking control for motor direction to prevent unintended reversals or stalls. - Simplifies external control: a momentary external forward or reverse command maintains motor motion after the switch is released, reducing operator effort. - Clear, safety-oriented limit behavior: short or transient limit signals reliably stop motion and require intentional restart, avoiding accidental restarts. How it works (functional summary) - PO versions are self-locking: when an external forward switch (K1) is pressed, the motor begins a forward rotation and remains rotating after the switch is released. The motor stops only when a reverse-turn signal (K2) or the forward-turn stop signal (SW1) is received. - Limit (stop) signals are trigger-type, level-activated inputs. If a forward rotation encounters a limit signal, motion is stopped immediately; the motor remains stopped even if the limit signal is removed. To resume forward movement, the forward rotation signal must be issued again. - Signal logic: inputs are active low. The product accepts standard three-wire NPN normally-open (NPN-NO) sensors. Inputs K1, K2, SW1, and SW2 conform to the same active-low specification. Features and attributes - Function: Self-locking directional control with defined limit/stop behavior for safe and predictable motor operation. - Compatibility: Accepts active-low control signals and three-wire NPN-NO sensors; K1, K2, SW1, SW2 are compatible with this signaling convention. - Performance behavior: Latching forward/reverse commands until a definitive stop or opposite command is received; limit inputs act as level-activated stops that persist until a restart command. - Size/material: Refer to the product datasheet or label for exact chassis dimensions and materials used; ensure mechanical compatibility with your installation. - Electrical interface: Designed for active-low control inputs; check system wiring to match NPN-NO sensor outputs or equivalent active-low drivers. Important operational notes - A short or transient limit signal will stop motion immediately and the controller will remain in the stopped state until a new forward or reverse command (as appropriate) is applied. - After a limit-triggered stop, removing the limit signal does not automatically restart motion. - Use sensors and switches that provide active-low outputs (or adapt outputs to active-low) to ensure reliable operation. - K1 = external forward command, K2 = external reverse command, SW1 = forward stop/limit, SW2 = reverse stop/limit (all follow the same active-low/sensor compatibility). Typical applications (practical scenarios) - Automated sliding gate: Use a momentary push-button (K1/K2) or NPN-NO sensor to start forward/reverse motion; SW1/SW2 act as final-limit switches to prevent overtravel. - Conveyor indexing and safety: Motor advances on a forward command and holds until a programmed stop or a limit switch (SW1) is reached; transient limit signals halt the conveyor and require a deliberate restart. - Motorized valve or actuator control: Simple forward/reverse control with reliable stop signals to protect mechanical endpoints and ensure controlled restarts. Compatibility checklist before installation - Confirm control inputs and sensors provide active-low signals or that you can convert them to active-low. - Verify use of three-wire NPN-NO sensors when applicable. - Map external controls to K1 (forward), K2 (reverse), SW1 (forward limit), and SW2 (reverse limit) per the wiring diagram in your product documentation. Safety and troubleshooting tips - Test limit switches and sensors for correct active-low operation before commissioning. - If the motor does not restart after a stop, ensure the appropriate forward/reverse command is reissued (the system will not auto-restart when a limit clears). - Consult the product wiring diagram and electrical ratings before connecting sensors or external switches. This description preserves the PO version behavior and signal requirements: self-locking forward/reverse control, trigger-type level-activated limit signals that latch stop conditions, and active-low input compatibility including three-wire NPN-NO sensors for K1, K2, SW1, and SW2.
  • ID Fruugo: 392781974-840135018
  • EAN: 525287158423

Livrări şi Returnări

Expediat în 24 de ore

  • STANDARD: GRATUIT - Livrare între lun. 01 decembrie 2025–mie. 17 decembrie 2025 - GRATUIT

Livrare de la China.

Facem tot ce ne stă în putinţă să ne asigurăm că produsele comandate de dumneavoastră vă sunt livrate în întregime şi conform specificaţiilor. Cu toate acestea, dacă primiţi o comandă incompletă sau articole diferite de cele comandate, sau aveţi alt motiv pentru care nu sunteţi mulţumit de comandă, puteţi returna comanda sau orice produse incluse în comandă şi primiţi o rambursare completă pentru articole. Vizualizaţi întreaga politică de returnare

Detalii de conformitate a produsului

Vă rugăm să consultați informațiile de conformitate specifice acestui produs prezentate mai jos.

Următoarele informații sunt furnizate de comerciantul independent terț care vinde acest produs.

Producător:
În continuare se prezintă informațiile de contact ale producătorului produsului relevant vândut pe Fruugo.

  • DelightDelight
  • Shenzhen Kulomi Technology Co., Ltd.
  • 401-13, Jinhe Building, 8 Xinhe Street, Maan Tang, Bantian
  • Longgang, Shenzhen, Guangdong
  • China
  • Shenzhen
  • CN
  • 518129
  • utopiadealsta@outlook.com
  • 13380310353

Persoana responsabilă în UE:
În continuare se prezintă informațiile de contact ale persoanei responsabile din UE. Persoana responsabilă este operatorul economic desemnat, cu sediul în UE, care este responsabil pentru obligațiile de conformitate referitoare la produsul relevant vândut în Uniunea Europeană.

  • Synertrade FR SAS
  • Synertrade FR SAS
  • 9 rue du Bat d'Argent
  • Lyon
  • France
  • Lyon
  • FR
  • 69001
  • info@syner-sarl.cn
  • (+33)774555006
  • https://seller.kuajingmaihuo.com/settle/qualification-service