DT-8908D Portable Digital Multimeter 6000 LCD Manual Range

229,00 RON
+ 29,99 RON Livrare

DT-8908D Portable Digital Multimeter 6000 LCD Manual Range

  • Marcă: Unbranded
Vândut de:

DT-8908D Portable Digital Multimeter 6000 LCD Manual Range

  • Marcă: Unbranded
Preţul de vânzare recomandat: 299,00 RON
Preţ: 229,00 RON
Economisiţi: 70,00 RON (23%)
Vândut de:
229,00 RON
+ 29,99 RON Livrare

În stoc

Acceptăm următoarele metode de plată

Descriere

DT-8908D High Accuracy Multimeter Tester Portable Manual Range Burn Proof Industrial LCD Voltmeter Item Type: Digital Multimeter Model: DT-8908D Material: ABS Battery: 4x1.5V AAA Battery (Battery Not Included) Purpose: It is suitable for electrical parameter measurement. Display: 6000 Digit LCD Display AC Response: True Effective Value Measurement Fuse: 630mA/250V Fuse; 20A/250V Fuse Polarity: Automatically Distinguish The Polarity, (-) Negative Over Range: "OL" Display Low Voltage Prompt: "Low Battery" Symbol Prompt Automatic Shutdown: 15 Minutes of No Operation Measuring Speed: 3 Times Per Second Operating Environment: 0℃ to 40℃ (4℉ to 104℉) Relative Humidity <70%RH Storage Temperature: -10℃ to 50℃ (14℉ to 122℉) Relative Humidity <80% Maximum Indoor Use Height: 2000m DC Voltage 600.0mV 0.1mV ±0.5% of rdg±8 dgts 6.000V 1mV 60.00V 10mV ±0.7% of rdg±5 dgts 600.0V 100mV ±0.7% of rdg±8 dgts 1000V 1V AC Voltage 6.000V 1mV ±1.2% of rdg±5 dgts 60.00V 10mV 600.0V 100mV 1000V 1V DC Current 60.00uA 0.01uA ±1.0% of rdg±5 dgts 60.00mA 10uA 600.0mA 100uA ±1.2% of rdg±8 dgts 20.00A 10mA ±2.0% of rdg±10 dgts AC Current 60.00mA 10uA ±1.0% of rdg±5 dgts 600.0mA 100uA ±1.2% of rdg±8 dgts 20.00A 10mA ±2.0% of rdg±10 dgts Resistance 600.0Ω 0.1Ω ±1.0% of rdg±5 dgts 6.000kΩ 1Ω ±1.5% of rdg±5 dgts 60.00kΩ 10Ω 600.0kΩ 100Ω 6.000MΩ 1kΩ ±2.5% of rdg±8 dgts 60.00MΩ 10kΩ Capacitance 60.00nF 10pF ±2.5% of rdg±8 dgts 600.0nF 0.1nF ±3.0% of rdg±8 dgts 6.000μF 1nF 60.00μF 0.01μF ±3.5% of rdg±10 dgts 600.0μF 0.1μF 6.000mF 1μF 60.00mF 10μF ±5.0% of rdg±10 dgts 100.0mF 100μF How e: DC Voltage Measurement: Note: Do not perform measurement at the moment when the power is turned on or off, as high voltage may damage the meter. 1. Place the function dial at the VDC (range: 600mV, 6V, 60V, 600V, 1000V) position; 2. Insert the black test lead into the negative COM port and the red test lead into the positive V port; 3. Touch the tip of the test lead to the test object to ensure that the electrode is correct (red connects the positive electrode, and black connects the negative electrode); 4. Read the voltage value on the display. When it is greater than 30V, the LCD will display a high voltage danger symbol. When it is greater than 1000V, the buzzer will sound. The red light is always on. If the electrode is reversed, a minus sign will be displayed before the value. AC Voltage Measurement: Warning: Please observe all safety precautions when measuring on wires with wires. Note: Do not perform measurement at the moment when the power is turned on or off, as high voltage may damage the meter. 1. Set the function dial to VAC/HZ (range: 6V, 60V, 600V, 1000V); 2. Insert the black test lead into the negative COM port and the red test lead into the positive/port; 3. Touch the tip of the test lead to the test object; 4. Read the voltage value on the display. When it is greater than 30V, the LCD will display a high voltage danger symbol. When it is greater than 1000V, the buzzer will sound and the red light will be on; 5. Short press the MODE button to enter the AC voltage frequency measurement mode, the measurement range is 45Hz~1KHz. DC Current Measurement: Note: The measurement time cannot exceed 10 seconds under the condition of 20A, otherwise the meter or test leads may be damaged. During the measurement, if the current cannot be estimated, the measurement should be started from the high range, and if necessary, the low range should be selected. 1. Insert the black test lead into the negative COM port; 2. Measure the current below 600mA DC, set the function dial to DC 60uA or mA (range: 60mA, 600mA), and insert the red test lead into the mA port; 3. When measuring DC 20A, set the function dial to the 20A gear and insert the red test lead into the 20A port; 4. Disconnect the power supply of the tested circuit, touch the black test lead to the negative pole of the tested circuit, and the red test lead to the positive pole of the tested circuit; 5. Turn on the power supply; 6. Read the current value on the display. When it is greater than 10A, the buzzer will sound and the red light will stay on. AC Current Measurement: Warning: To prevent electric shock, do not measure on a circuit with a voltage exceeding 250V. Note: The measurement time cannot exceed 10 seconds under the condition of 20A, otherwise the meter or test leads may be damaged. During the measurement, if the current cannot be estimated, the measurement should be started from the high range, and if necessary, the low range should be selected. 1. Insert the black test lead into the negative COM port; 2. When measuring 600mA, put the function keyboard in the AC 60mA, 600mA gear position, and insert the red test lead into the mA port; 3. When measuring 20A,
  • ID Fruugo: 405816935-860532931
  • EAN: 4681326875051

Livrări şi Returnări

Expediat în 24 de ore

  • STANDARD: 29,99 RON - Livrare prin mie. 15 octombrie 2025

Livrare de la China.

Facem tot ce ne stă în putinţă să ne asigurăm că produsele comandate de dumneavoastră vă sunt livrate în întregime şi conform specificaţiilor. Cu toate acestea, dacă primiţi o comandă incompletă sau articole diferite de cele comandate, sau aveţi alt motiv pentru care nu sunteţi mulţumit de comandă, puteţi returna comanda sau orice produse incluse în comandă şi primiţi o rambursare completă pentru articole. Vizualizaţi întreaga politică de returnare

Detalii de conformitate a produsului

Vă rugăm să consultați informațiile de conformitate specifice acestui produs prezentate mai jos.

Următoarele informații sunt furnizate de comerciantul independent terț care vinde acest produs.

Producător:
În continuare se prezintă informațiile de contact ale producătorului produsului relevant vândut pe Fruugo.

  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Room201,AreaB,No.280,Zhongshan Avenue East
  • Huangpu
  • Guangzhou
  • Guangdong
  • China
  • 518000
  • firzen.pan@gmail.com
  • +8619128656319

Persoana responsabilă în UE:
În continuare se prezintă informațiile de contact ale persoanei responsabile din UE. Persoana responsabilă este operatorul economic desemnat, cu sediul în UE, care este responsabil pentru obligațiile de conformitate referitoare la produsul relevant vândut în Uniunea Europeană.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659