jixopn DC6-40V Battery Charge/Discharge Module LED Digital Display Integrated Voltmeter

84,00 RON
Livrare GRATUITĂ

jixopn DC6-40V Battery Charge/Discharge Module LED Digital Display Integrated Voltmeter

  • Marcă: Unbranded
Vândut de:

jixopn DC6-40V Battery Charge/Discharge Module LED Digital Display Integrated Voltmeter

  • Marcă: Unbranded

84,00 RON

Economii 55,00 RON (39%)

Preț recomandat

139,00 RON
În stoc
Livrare GRATUITĂ

Politica de retur pe 14 zile

Vândut de:

84,00 RON

Economii 55,00 RON (39%)

Preț recomandat

139,00 RON
În stoc
Livrare GRATUITĂ

Politica de retur pe 14 zile

Metode de plată:

Descriere

jixopn DC6-40V Battery Charge/Discharge Module LED Digital Display Integrated Voltmeter

Specification: _x005f_x000D_ Origin: Mainland China _x005f_x000D_ Type: Module _x005f_x000D_ Condition: New _x005f_x000D_ Supply voltage: DC6-40V, voltage detection range DC 0-60V, suitable for all kinds of batteries below 60V, voltage test error ±0.1V _x005f_x000D_ Charge and discharge time (OP) range: 0-999 minutes _x005f_x000D_ Product weight: 29g _x005f_x000D_ Product size: 64*40*10mm/2.52*1.57*0.39inch _x005f_x000D_ _x005f_x000D_ How to set the parameters _x005f_x000D_ 1. First determine the working mode of the relay; _x005f_x000D_ 2. according to the working mode of the relay, in the main interface (when the module is powered on, it will flash down the current working mode (default U-1 mode), then enter the main interface,) "long press the SET key for 2 seconds and then release it" to enter the mode selecting interface, and select the mode to be set (U-1~U-6) by short pressing the UP and DOWN keys. -6); _x005f_x000D_ 3. After selecting the mode to be set (e.g. U-1), short press the SET key to set the corresponding parameter, at this time the parameter to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP on-time), adjust the parameter value through UP and DOWN, support long press (rapid increase or decrease) and short press (increase or decrease by 1 unit); short press the SET key to set the next parameter of the current mode, the process is the same as above; short press the SET key to set the next parameter of the current mode, the process is the same as above. The process is the same as above. 4; _x005f_x000D_ 4. After setting the parameters of the selected mode, long press the SET key for 2 seconds and then release it, the currently set mode will blink, and then return to the main interface, the parameters are set successfully, it's very simple! _x005f_x000D_ 5. In the main interface, short press DOWN button to switch voltage and time, very simple. _x005f_x000D_ Mode selection interface: long press the SET button to enter, set the completion, long press the SET button to exit, back to the main interface, very simple! _x005f_x000D_ _x005f_x000D_ Note: _x005f_x000D_ Due to the different monitor and light effect, the actual color of the item might be slightly different from the color showed on the pictures. Thank you! _x005f_x000D_ Please allow 1-2cm measuring deviation due to manual measurement. _x005f_x000D_ _x005f_x000D_ _x005f_x000D_ Included: _x005f_x000D_ 1 X Discharge Module 1. Battery Charging and Discharging Control: Integrated voltmeter Automatically shuts off power after setting, providing control and safety. 2. Adjustable Charging and Discharging Time: Switch relay module allows users to set specific time intervals for charging and discharging. 3. Serial Communication Function: Switch relay module enables realtime monitoring of relay status through serial communication. 4. Additional Signal Output: Battery charge/discharge module provides an extra signal output that controls other devices when the relay is activated. 5. Emergency Stop Function: There is one key emergency stop function (STOP key), with reverse connection protection, reverse connection does not burn; working mode: upper voltage limit: UL1, lower voltage limit nL1, the upper voltage limit should be greater than the lower voltage limit (UL1>nL1).U1: Charge Measurement: when the measured voltage is lower than the lower voltage limit, the relay is absorbed; higher than the upper voltage limit, the relay is disconnected; U2: Charge Measurement Time Control: set the charging time ( OP); when the measured voltage is lower than the lower limit voltage, the relay is absorbed and starts counting down the OP time after absorption, when the time is up, the relay is disconnected; higher than the upper limit voltage, the relay is disconnected; U3: Discharge Detection: when the measured voltage is lower than the lower limit voltage, the relay is disconnected, higher than the upper limit voltage, the relay is absorbed; U4: Discharge Detection Time Control: set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay will be absorbed, after absorbed, it will start counting down the OP time, when the time is up, the relay will be disconnected; when the measured voltage is lower than the lower limit voltage, the relay will be disconnected; U intrazone absorption: when the measured voltage is between upper limit voltage and lower limit voltage, the relay will be absorbed and disconnected in other cases; U6: Outofzone absorption: the relay will be absorbed when the measured voltage is lower than the lower limit voltage or higher than the upper limit voltage and disconnected in other cases. U6: Outofrange engagement: the relay is engaged when the measured voltage is below the lower or above the upper limit, otherwise it is disengaged.
  • ID Fruugo: 433533760-910100875
  • EAN: 9778424983698

Informații privind siguranța produsului

Vă rugăm să consultați informațiile despre siguranța produsului specifice acestui produs prezentate mai jos

Următoarele informații sunt furnizate de comerciantul independent terț care vinde acest produs.

Avertismente de siguranță: Warning to keep away from water to prevent electric shocks.
Ingrediente: Other

Livrări şi Returnări

Expediat în 3 zile

  • STANDARD: GRATUIT - Livrare între joi 15 ianuarie 2026–vin. 16 ianuarie 2026 - GRATUIT

Livrare de la China.

Facem tot ce ne stă în putinţă să ne asigurăm că produsele comandate de dumneavoastră vă sunt livrate în întregime şi conform specificaţiilor. Cu toate acestea, dacă primiţi o comandă incompletă sau articole diferite de cele comandate, sau aveţi alt motiv pentru care nu sunteţi mulţumit de comandă, puteţi returna comanda sau orice produse incluse în comandă şi primiţi o rambursare completă pentru articole. Vizualizaţi întreaga politică de returnare

Detalii de conformitate a produsului

Vă rugăm să consultați informațiile de conformitate specifice acestui produs prezentate mai jos.

Următoarele informații sunt furnizate de comerciantul independent terț care vinde acest produs.

Producător:
În continuare se prezintă informațiile de contact ale producătorului produsului relevant vândut pe Fruugo.

  • Chen ShaoMao
  • Lixian Maisite Trading Co., Ltd.
  • Group 8
  • Wugong Village
  • Xiaodukou Town
  • Lixian County
  • CN
  • 415500
  • qiandangxiaoqdx@outlook.com
  • 13192770024

Persoana responsabilă în UE:
În continuare se prezintă informațiile de contact ale persoanei responsabile din UE. Persoana responsabilă este operatorul economic desemnat, cu sediul în UE, care este responsabil pentru obligațiile de conformitate referitoare la produsul relevant vândut în Uniunea Europeană.

  • e Vatmaster Consulting GmbH
  • e Vatmaster Consulting GmbH
  • RaiffeisenstraBe 2 B11
  • Rodgau
  • DE
  • 63110
  • contact@evatmaster.com
  • 49 61062699873