Current Detection Sensor Module Digital Display 4‑20mA Relay Component DC 12V

149,00 RON
Livrare GRATUITĂ

Current Detection Sensor Module Digital Display 4‑20mA Relay Component DC 12V

  • Marcă: Unbranded
Vândut de:

Current Detection Sensor Module Digital Display 4‑20mA Relay Component DC 12V

  • Marcă: Unbranded

149,00 RON

Economii 20,00 RON (11%)

Preț recomandat

169,00 RON
Doar 5 rămase în stoc
Livrare GRATUITĂ

Politica de retur pe 14 zile

Vândut de:

149,00 RON

Economii 20,00 RON (11%)

Preț recomandat

169,00 RON
Doar 5 rămase în stoc
Livrare GRATUITĂ

Politica de retur pe 14 zile

Acceptăm următoarele metode de plată

Descriere

Current Detection Sensor Module Digital Display 4‑20mA Relay Component DC 12V

Features 1.Composed of professional PCB materials, stable performance and long service life. 2.Increase the power supply anti‑reverse protection to reduce the risks of work errors and improve work efficiency. 3.With three‑digit display, three‑button adjustment is convenient and easy to use. 4.The module with small size, easy to carry and store, convenient to use and with good performance. 5.Great workmanship, with strict quality control and quality assurance, high safety factor, can be used with peace of mind. Specification Item Type: Current Detection Sensor Module Material: PCB Working Current: Standby: 12mA, Working: 56mA Working Voltage: DC12V Digital Display Life: ≥50,000 hours Relay Life: ≤100,000 times Digital Tube: 3 in 1 Working Temperature: -20℃~75℃ Measuring Range: 0-25mA Detection Signal: 4-20ma Product Features: 4-20ma Current Detection: After the module is powered on, the PX is initially displayed and the currently set mode is displayed. At this time, the mode can be adjusted by pressing the "+" and "-" buttons. It will enter the real-time display of the measured current after 4s. Three buttons to set the upper and lower limits and function mode selection Interface Description: Input Positive Pole: Connect to the positive pole of the power supply Negative Pole: Connect to the negative pole of the power supply AO: 4-20ma signal input COM: It is connected to the negative pole of the power supply Output NO: NO end COM: Public NC: NC end Several Modes Can be Set as Follows: (Long press "-" for 3s to enter the adjustment mode) P-1: Suction exceeds the set value, but is disconnected below the set value; the measured value exceeds the lower limit value and the relay suctions, and disconnects below the lower limit value. P-2: Disconnect when the value exceeds the set value, but is lower than the suction; when the measured value exceeds the lower limit, the relay is disconnected, and the suction is lower than the lower limit. P-3: Suction in the interval and disconnected outside the interval; the measured value is between the upper limit and the lower limit and the relay sucks, otherwise it is disconnected P-4: Disconnected in the interval, sucked outside the interval; the relay is disconnected between the upper limit and lower limit of the measured value, otherwise sucked P-5: Disconnect below the lower limit, and absorb above the upper limit; when the measured value exceeds the lower limit, the relay will disconnect, and the relay will absorb above the upper limit. P-6: Suction is lower than the lower limit, and it is disconnected above the upper limit; the measured value exceeds the lower limit and the relay is suctioned, and the relay is disconnected above the upper limit. Setting Instructions (for The Convenience Of Description, Use K1 For The setting key, K2 for the + key, and K3 for the-key): Key Description: "K1 shift/adjust; K2+; K3-/mode selection Press the K1 key, the first digit flashes, adjust the lower limit of hundreds, press K2, K3 to adjust 0~1 change Press the K1 button, the second digit will flash, adjust the tens digit of the lower limit, press K2, K3 to adjust 0-9 changes Press K1 key, the third lower third digit flashes, adjust the lower limit one digit, press K2, K3 to adjust 0-9 change Press the K1 key, the 4th, lower, and fourth digits will flash, adjust the upper limit of hundreds, press K2, K3 to adjust 0~1 changes Press K1 key, the 5th bottom fifth digit flashes, adjust the upper limit ten digits, press K2, K3 to adjust 0-9 changes Press K1 key, the 6th, lower and sixth digits will flash, adjust the upper limit one digit, press K2, K3 to adjust 0-9 changes Press the K1 key for the 7th time, the digital tube is not flashing, it displays the measured current value Package List 1 x Current Detection Sensor Module
  • ID Fruugo: 271671896-602233680
  • EAN: 9140150437835

Informații privind siguranța produsului

Vă rugăm să consultați informațiile despre siguranța produsului specifice acestui produs prezentate mai jos

Următoarele informații sunt furnizate de comerciantul independent terț care vinde acest produs.

Etichete de siguranță pentru produse

CE Mark
Avertismente de siguranță: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

Livrări şi Returnări

Expediat în 2 zile

  • STANDARD: GRATUIT - Livrare între lun. 29 decembrie 2025–vin. 02 ianuarie 2026 - GRATUIT

Livrare de la China.

Facem tot ce ne stă în putinţă să ne asigurăm că produsele comandate de dumneavoastră vă sunt livrate în întregime şi conform specificaţiilor. Cu toate acestea, dacă primiţi o comandă incompletă sau articole diferite de cele comandate, sau aveţi alt motiv pentru care nu sunteţi mulţumit de comandă, puteţi returna comanda sau orice produse incluse în comandă şi primiţi o rambursare completă pentru articole. Vizualizaţi întreaga politică de returnare